Technical indicators (TAC-0100-3402)
Working temperature: -10 C -65 C
Environmental humidity: 5%-95%
System power: AC 90V-265V
Controller power supply: AC 24V (allowing range 9V-36V)
Battery interface: DC 7.5AH 12V
Power consumption: 80mA (DC 12V)
Communication specification: RS-232 (9600bps)
Networking distance: 1200m
Card reader to controller distance: "100m (STP-8)
Open door delay: 1-255 seconds adjustable
Each controller controls the number of locks: 4
Managing user card number: 12480
Hold code number: 255
Combined card number: 510
Access records: 10920
Button to open the door and a variety of alarm records: 9360
Reader input format: 26bit, 32bit, 35bit, 37bit, 40bit, or ABA
The number of input and output: the reader four, lock four, door state detection input four, open the door switch four, four alarm input, custom input eight, four auxiliary output
Controller size: 238mm * 145mm
Control box size: 360mm x 300mm x 75mm