Technical index
The typical maximum reading distance
II ProxCard card - up to 3 (7.5cm)
II ISOProx card - up to 2.5 (6.25cm)
II DuoProx card - up to 2.5 (6.25cm)
II ProxKeyTM key - up to 1.5 (3.7cm)
Plus ProxCard card - up to 1 (2.5cm)
The size of
2.75 x 5.25 x 1.375 (13.33 x 6.98 3.49cm x).
The power / current requirements
10-15VDC, reverse voltage protection.
The proposed linear power supply, 150mA@12VDC......
The relay output
Trigger relay - C type, can be converted to 4A@30VDC...
Auxiliary relay - C type, can be converted to 1A@30VDC...
The monitor input
Portal position - N.O. dry contact
Request withdrawal - N.O. dry contact
The buzzer
4000Hz, can be closed
The LED
Double color (red / green) light, yellow, infrared (connected handheld printer)
The operating temperature
-22 degrees Fahrenheit to 150 degrees F (degrees Celsius to 65 degrees C)
The operating humidity
Relative humidity from 5% to 95%, non setting
The cable distance
Remote reader module - 10 feet (3 meters)
Wei root interface - 500 feet (152 meters)
The proposed use of 1295C ALPHA (22AWG) 5 core into a beam full screen
Cable or equivalent product
The operation
Trigger time: 1-99 seconds (adjustable)
Trigger mode: access timer or trigger / door lock
Open door time: 10-990 seconds (adjustable)
The induction card programming
26 bit format - batch registration
OEM special format - to produce induction card registration
The place code option (only 26)
Check the location code and the induction card ID
Only check the location code (which can be accepted by any ID number).
The approval
FCC - pending approval of the CE sign - pending approval