Technical index
The typical maximum reading distance
II ProxCard (1326) card - up to 29 "(73cm)
II ISOProx (1386) card - up to 20 "(50cm)
II ProxKey (1346) Key Pendant - up to 17 "(43cm)
Proximity&MIFARE HID? (1431) - up to 20 "(50.8cm)
The size of
11.8 x 11.8 x 1 (30 x 30 x 2.54 cm)
The material: UL94
The power supply can be set: 12 or 24VDC. Proposed use of linear power supply.
The current requirements:
DC electric 12V: average 200mA, peak 700 mA)
DC power 12V: average 200mA, peak 700 mA
The operating temperature: -22 degrees Fahrenheit (-30 degrees Celsius to 150 DEG F to 65 DEG C)
The weight: 51 ounces (1.4 kg)
The transmission frequency: 125kHz
The certificate:
- Canadian /UL 294 certification: access control system unit
Us FCC certification
- Canadian certification
- CE logo, the European Union's fifteen countries under the R&TTE directive (EN60950-ITE electrical safety; 330-SRD EN300 and ETS 300 683-EMC)
- C-Tick logo in Australia
- New Zealand EMC
The cable distance:
Wei root interface: 500 feet (152 meters)
Clock - data interface: 50 feet (15 meters)
RS-232:50-200 feet (15-61 feet)
The proposed use of ALPHA1295 (22AWG) 5 core into a bunch of all shielded cable or equivalent products.
LED or call device control may also require other wires.
Recommended using ALPHA1297 cable.
7/00 LIT5375DS replace 12/97
Function introduction
Installation: installed on the non metallic surface to obtain the best read distance.
Audio visual: in the production of induction card, red LED will flash green, the caller will make a sound. Multi - color LED and call can also be controlled by the host system.
Diagnosis: when the reader is powered up, the internal will carry out the routine test, verify the installation settings, determine the internal control of the LED and the call device, and perform the initialization of the card reader.
Indoor / outdoor design: the card reader is encapsulated in the box firmly within the polycarbonate, can perform initialization. In addition, external loopback test without other test equipment, from the sun and rain, to resist harsh environment, is not easy to be damaged, to ensure on any occasion are reliable in performance.
Easy interface connection: can be connected with all existing, clock and data, RS-232, RS-422 and RS-485 protocol access control system. The serial interface supports 1200, 2400, 4800 and 9600 baud rate.
Security: with a protective switch, the reader will be issued when the card reader is damaged. Can distinguish up to 85 bit format.
Bao: since the date of shipment, the card reader material and the production of defects for life insurance (see the full use of insurance policies).
Part number
Basic part number: 5375
Description: Wei root interface, dark gray, three steady state LED, the internal call is connected
Option:
LED and call for operation
Custom tags